Eur Rev Med Pharmacol Sci 2022; 26 (20): 7349-7358
DOI: 10.26355/eurrev_202210_30004

Swept-source endoscopic optical coherence tomography real-time imaging system based on GPU acceleration for axial megahertz high-speed scanning

J. Lyu, L. Ren, Q.-Y. Liu, Y. Wang, Z.-Q. Zhou, Y.-Y. Chen, H.-B. Jia, Y.-G. Tang, M. Li

Division of Life Sciences and Medicine, School of Biomedical Engineering (Suzhou), University of Science and Technology of China, Suzhou, China. limin@sibet.ac.cn


OBJECTIVE:  In order to solve the problem of image real-time processing and correction for high-speed endoscopic swept-source optical coherence tomography (SS-OCT), we highly optimize a computer-unified device architecture-based platform and use a field-programmable gate array to summarize the application experience.

MATERIALS AND METHODS: We use the Half-Sync/Half-Asyn mode to optimize memory in order to build a high-throughput data thread pool for CPU. We use asynchronous streaming architecture to multiplex multiple threads at high speed to accelerate data processing. At the same time, we design a rotary scanning position information encoding feedback module to suppress image drift, which can realize 25ns logic-timing sequence synchronization control through FPGA 40MHz clock.

RESULTS: The maximum complete attainable axial-scan-processing rate (including memory transfer and display of B-scan frames) is 3.52 MHz for a 16-bit pixel depth and A-scans/s of 1024 pixels. To our knowledge, this is the fastest processing rate reported to date with a single-chip graphical processing unit for SS-OCT. Finally, the established high-speed SS-OCT is used to image mouse esophagus and human fingers, and the output images are stable. When the image size is 1024 × 1024 pixels, the real-time imaging rate is 200 frames per second.

CONCLUSIONS: This paper develops a real-time image processing and reconstruction technology suitable for high-throughput SS-OCT systems, which can have high-density operation and efficient parallelism, while suppressing high-speed image drift. It lays the foundation for the non-destructive, in vivo, non-staining, fast and convenient early tumor diagnosis of high-speed endoscopic SS-OCT.

Free PDF Download

To cite this article

J. Lyu, L. Ren, Q.-Y. Liu, Y. Wang, Z.-Q. Zhou, Y.-Y. Chen, H.-B. Jia, Y.-G. Tang, M. Li
Swept-source endoscopic optical coherence tomography real-time imaging system based on GPU acceleration for axial megahertz high-speed scanning

Eur Rev Med Pharmacol Sci
Year: 2022
Vol. 26 - N. 20
Pages: 7349-7358
DOI: 10.26355/eurrev_202210_30004