Lung protection effect of EIT-based individualized protective ventilation strategy in patients with partial pulmonary resection
J. Zha, Y.-J. Yu, G.-R. Li, S.-C. Wang, S.-G. Qiao, C. Wang, H.-L. Bo Department of Anesthesiology, The Second Affiliated Hospital of Wannan Medical College, Wuhu, China. anesthesia_icu@163.com
OBJECTIVE: This study aimed to evaluate the lung protection effect of an individualized protective ventilation strategy based on lung impedance tomography (EIT) technology in patients with partial pulmonary resection.
PATIENTS AND METHODS: Eighty patients of any gender, American Society of Anesthesiologists (ASA) classification I-II, age 30-64 years and body mass index (BMI) 18-28 kg/m2 who underwent elective thoracoscopic partial lung resection were selected and divided into 2 groups (n=40) using the random number table method: [positive end-expiratory pressure (PEEP) by electrical impedance tomography (EIT)] PEEPEIT group (experimental group) and control group. The PEEPEIT group used volume-controlled ventilation after one-lung ventilation, setting a tidal volume of 6 ml/kg and titrating the optimal PEEP value by EIT. Group C used volume-controlled ventilation after one-lung ventilation, setting a tidal volume of 6 ml/kg and a PEEP of 5 cm H2O. Clinical data were collected and recorded at 5 min after double lung ventilation (T0), single lung ventilation, 30 min after PEEP setting (T1), 60 min after PEEP setting (T2), the end of surgery, 10 min after resumption of double lung ventilation (T3) and 10 min after removal of the tracheal tube (T4), and serum surface active substance-associated protein-A (SP-A) concentrations were measured at T0, T3 and 1 d after surgery (T5).
RESULTS: PEEP values were higher in the PEEPEIT group than in the control group at T1 and T2 (p-value <0.05); oxygenation index (OI) was higher in the PEEPEIT group compared to the control group at T2 and T3 (p-value <0.05); pulmonary dynamic compliance (Cdyn) was higher in the PEEPEIT group compared to the control group at T1 and T2 (p-value <0.05); intrapulmonary shunt rate (Qs/Qt) was lower in the PEEPEIT group compared to the control group at T1, T2 and at T3, the intrapulmonary shunt rate (Qs/Qt) was reduced in the PEEPEIT group compared to group C (p-value <0.05); at T5, the SP-A protein was reduced in the PEEPEIT group compared to group C. There was no statistically significant difference in the incidence of postoperative pulmonary complications between the two groups (p-value >0.05).
CONCLUSIONS: The EIT-guided individualized protective ventilation strategy has a lung-protective effect in patients undergoing thoracoscopic partial lung resection.
Free PDF DownloadThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
To cite this article
J. Zha, Y.-J. Yu, G.-R. Li, S.-C. Wang, S.-G. Qiao, C. Wang, H.-L. Bo
Lung protection effect of EIT-based individualized protective ventilation strategy in patients with partial pulmonary resection
Eur Rev Med Pharmacol Sci
Year: 2023
Vol. 27 - N. 12
Pages: 5459-5467
DOI: 10.26355/eurrev_202306_32782