Eur Rev Med Pharmacol Sci 2024; 28 (7): 2770-2776
DOI: 10.26355/eurrev_202404_35905

Factors influencing the therapeutic failure of high-flow nasal cannula oxygen humidification in patients with interstitial pneumonia complicated by respiratory failure

W.-P. Zhao, W. Zhang, J.-P. Li, L.-L. Qu

Nursing Department, The First People’s Hospital of Baiyin City, Gansu Province, Baiyin City, Gansu Province, China. 13893095721@163


OBJECTIVE: The aim of this study was to explore the factors influencing the treatment failure of high-flow nasal cannula (HFNC) therapy in patients with interstitial pneumonia (IP) complicated by respiratory failure.

PATIENTS AND METHODS: A total of 158 patients with IP and respiratory failure treated with HFNC in our hospital from January 2020 to August 2023 were selected as the study population. Based on treatment efficacy, they were categorized into the HFNC treatment failure group and the HFNC treatment success group. Clinical data were compared between the two groups. Multiple logistic regression analysis was employed to identify independent factors influencing treatment failure, and the predictive value of these factors for HFNC treatment failure was assessed using receiver operating characteristic (ROC) curve analysis.

RESULTS: After 7 days of HFNC treatment, among the 158 patients with IP and respiratory failure, 25 (15.8%) declared treatment failure, while the remaining 133 (84.2%) showed treatment success. Patients in the HFNC treatment failure group had significantly higher age, duration of IP, pre-treatment respiratory rate, C-reactive protein (CRP), and controlling nutritional status (CONUT) scores compared to the HFNC treatment success group. The PaO2/FiO2 ratio, left ventricular ejection fraction, and Glasgow Coma Scale (GCS) were significantly lower in the HFNC treatment failure group (p<0.05). Multiple logistic regression analysis revealed that pre-treatment PaO2/FiO2 ratio, CRP, CONUT, and GCS scores were independent factors influencing HFNC treatment failure in patients with IP and respiratory failure (p<0.05). Lower PaO2/FiO2 ratio and GCS scores, and higher CRP and CONUT scores were associated with an increased risk of HFNC treatment failure. ROC curve analysis indicated that pre-treatment PaO2/FiO2 ratio, CRP, CONUT, and GCS scores in patients with IP and respiratory failure had a high predictive value for HFNC treatment failure (p<0.05).

CONCLUSIONS: The HFNC failure rate in patients with IP and respiratory failure is 15.8%. Pre-treatment PaO2/FiO2 ratio, CRP, CONUT, and GCS scores are independent factors associated with HFNC treatment failure and warrant clinical attention.

Free PDF Download

To cite this article

W.-P. Zhao, W. Zhang, J.-P. Li, L.-L. Qu
Factors influencing the therapeutic failure of high-flow nasal cannula oxygen humidification in patients with interstitial pneumonia complicated by respiratory failure

Eur Rev Med Pharmacol Sci
Year: 2024
Vol. 28 - N. 7
Pages: 2770-2776